Load Cells CAS BSA

Load cell BSA

Shear Beam Load Cells BSA.

Application: Floor Scales, Tank/Vessel/Hopper Scales.

Features:

OIML C3 Approved (OIML R60).

NTEP III 5,000S Approved (Handbook 44).

Options:

OIML C3 Approved (OIML R60).

NTEP III 5,000S Approved (Handbook 44)(Pound & Imperial thread Ver.).

Accessory Options:

Bolt type_TW.

Ball & Safety guide bar type_TWE.

Pivot end loading version_Tend (1t, 2t).

Cable (4 core):

Exc+ Exc- Sig+ Sig- shield
Red White Green Blue Black

SPECIFICATION

Max. Capacity (Rated Load) kg 250, 500, 1K, 2K, 3K, 5K
Rated Output mV / V 3.0 ± 0.0075
Zero Balance mV / V 0.0 ± 0.03
Accuracy Class D3 C3
Non-Linearity %R.O. ≤0.03 ≤0.025
Hysteresis %R.O. ≤0.03 ≤0.025
Combined Error %R.O. ≤0.03 ≤0.025
Repeatability %R.O. ≤0.01 ≤0.01
Creep for 30min. %R.O. ≤0.03 ≤0.017
Return for 30min. %R.O. ≤0.03 ≤0.017
Resolution ≤1/3000 ≤1/4000
Division mV / V 0.001 0.00075
Temperature Effect on
_Zero Value %/10°C ≤0.028 ≤0.014
_Output Value %/10°C ≤0.015 ≤0.011
Excitation
_Recommended V 10
_Maximum V 15
Resistance
_Input 350±3.5
_Output 350±3.5
_Insulation MΩ >2000
Compensated Temperature Range °C -10 to +40
Operating Temperature Range °C -30 to +80
Material & Plate Nickel Plated Steel
Cable Specification Ø5.4 x 4p x 5M (Urethane)
Safety Overload %R.L. 150%R.L.
Platform Size mm Without Limit

Dimension(mm)

Kích thước lắp đặt Load cells CAS BSA

Load cells CAS BSA

 

Type

CAP A B C D E F G H I J K

BSA-250L

250kgf

25.4 76.2 130 32 32 15.8 13.5 13.5 16 M12x1.75 52

BSA-500L

500kgf

BSA-1

1tf

BSA-2

2tf

BSA-3

3tf

38.1 95.3 171.5 38 38 19 20 20 19 M18x1.5 76.2
BSA-5

5tf

 

CAP

Foot Type Force

250kgf ~ 2tf

M12x1.75 (10.9)

100Nm

3tf~5tf M18x1.5 (10.9)

350Nm

CAS_BSA Shear Beam Load cell Datasheet Document

Leave a Reply