Tag: UniCell

Digital Load Cell KDS-D 30tf

CASC KDS-D / KDB-D is a digital double-ended shear beam load cell built for truck scales, railway scales and silo weighing systems. The load cell converts the weighing signal to digital data close to the sensing point, then transmits it over RS-485 communication for improved stability on long …

Load Cell Troubleshooting

Load cell problems can appear as unstable readings, zero drift, corner error, poor repeatability, overload damage or communication failure. Good troubleshooting starts with symptoms, then separates mechanical, electrical, environmental and calibration causes. UNICELL Sensors supports troubleshooting for truck scales, tank weighing, silo weighing and heavy industrial weighing applications. …

Truck Scale Calibration

Truck scale calibration confirms that the scale reads correctly across the platform, not only at one point. A good calibration procedure includes mechanical inspection, zero check, span calibration, corner adjustment, repeatability check and final service record. UNICELL Sensors supports calibration review for analog and digital truck scale systems …

Install Digital Load Cells

Digital load cells can improve diagnostics, signal stability and service speed, but only when the mechanical installation, wiring, addressing and calibration are done carefully. For truck scales, the installation must consider foundation level, mounting kits, cable protection, grounding, load cell address mapping and corner adjustment records. UNICELL Sensors …

Digital vs Analog Load Cells

Load cells are the heart of an electronic weighing system. They convert force from a truck scale, silo, tank, hopper or platform into a signal that can be processed by a weighing indicator, controller, PLC or weighing software. Analog load cells are familiar, practical and cost-effective. Digital load …